HomeProductsPortable Total Hydrocarbon AnalyzerAoma X5 Portable Total Hydrocarbon Analyzer/Volatile Organic Compounds Analyzer

Aoma X5 Portable Total Hydrocarbon Analyzer/Volatile Organic Compounds Analyzer

The Aoma X5 is a portable total hydrocarbon analyzer that makes VOC leaks "visible." Weighing only 1.4 kg, it features a 3.5-inch touchscreen and integrates multidimensional image overlay and AI-powered voice assistance, making detection more intuitive and convenient.

Share:

Product Introduction

The X5 integrates photo/video capture and real-time gas detection functions, providing dual presentation and dual guarantees to achieve intuitive and traceable gas monitoring. Its built-in AI detection assistant combined with automatic calibration further simplifies on-site operations, eliminating operational barriers.

01 Product features:

  • Outstanding gas visualization and quantification capabilities:

The built-in camera, time, location, and management features enable quantitative visualization of gas detection, allowing measurement of leakage type and severity without auxiliary equipment, while effectively recording test results.

The revolutionary quantitative analysis function reduces preheating time by several orders of magnitude and improves calibration efficiency.

  • Ergonomically designed for a more comfortable operation:

A highly integrated FID-type VOC detector, designed for one-handed operation without requiring external devices.

The 3.5-inch color touchscreen provides a more comfortable experience for both device operation and interaction.

  • Security and convenience:

The system features both intrinsically safe and explosion-proof designs, with an explosion-proof rating of Ex db ia IIC T4 Gb.

The system features replaceable low-pressure solid-state hydrogen storage tanks, enabling simple and convenient hydrogen charging while meeting aviation-grade safety standards for storage and transportation.

  • Record and report test results effectively:

With built-in Wi-Fi and Bluetooth, it connects to smartphones or tablets for easy image editing and cloud storage.

Built-in camera photography and time positioning management enable quantitative visualization of gas detection. Multi-format storage effectively records detection results.

  • Feature extension:

Optional sensors for PID, oxygen, carbon monoxide, carbon dioxide, and hydrogen sulfide can be installed to support multi-scenario applications.

RFID electronic tags are optional, which can be integrated with the instrument inventory management platform software to enable intelligent instrument management.

02 after-sale service :

  • Free Quick Backup: Your device is covered for 1 year, with free backup service provided during the warranty period.
  • Enjoy free annual factory maintenance and lifetime repairs, with only spare parts costs charged.

03 Technical parameters and configurations:

essential parameterParameter range
product descriptionX5 Total Hydrocarbon Analyzer/Volatile Organic Compounds Analyzer
Measured componentMost organic compounds
Detector typeFID and PID/O2/CO/CO2/H2S (optional)
Precision modeppm/ppb
Interaction3.5-inch color LCD touch display; five-function buttons, trigger key, AI voice
Range (ppm)FID: 0~100,000 μmol/mol methane (adjustable range)PID: 0~2000 μmol/mol isobutene (adjustable range)
Input/OutputBluetooth, Wi-Fi, USB
goingEnvironmental temperature: -25°C to +50°C; Relative humidity (0% to 95% RH)
dynamic pressure compensationEPC Pressure Automatic Dynamic Control Adaptation to Meet the Stability and Accuracy in Multimodal Scenarios
duration of flight+25°C ambient temperature and approximately 13 hours for general use
Total weight (including battery and gas cylinder)1.3±0.05 kg
Machine size258mm×168mm×97.7 mm
detector 
Accuracy (display error)FID: ±2% of the instrument reading, for methane concentrations ranging from 1.0 to 10,000 ppm;PID: Instrument–readout ±2%,0.5 to 500 ppm isobutene;The error of the detector reading is ≤±5% at 50℃ and-20℃.
resolution ratio0.01μmol/mol
repetitivenessFID: Instrument ± 2% (500 ppm methane)PID: Instrument ±1% (100 ppm isobutene)
collimationFID:≤2%
stabilityThe instrument operated continuously for 8 hours, with a measurement drift of ≤ ±5%.
detection limitThe lower limit of detection was defined as seven times the standard deviation of the interpeak noise.FID instrument-0.5 ppm methanePID instrument-0.5 ppm isobutene
sampling velocityThe nominal value is displayed at the sample probe inlet, rated at 0.7 L/min.
preheating time≤5min
actual lifeApproximately 6000 hours
Measurement and Analysis 
calibration of measurementSupports multi-point calibration, with a minimum of two points required
calibration validityApproximately 168 hours for general use
Response time (T90)sensitivityFID: Achieves 90% of the final value in less than 3.0 seconds when using 10,000ppm methanePID: Using 500ppm isobutylene, reach 90% of the final value in less than 3.0 seconds
Reset time (T90)sensitivityFID: Achieves 90% of the final value in less than 3.0 seconds when using 10,000ppm methanePID: Using 500ppm isobutylene, reach 90% of the final value in less than 3.0 seconds
take notesReal-time value, maximum value (manual clearing, automatic storage), average value, curve trend
Testing unitLocalized unit adjustment, ppm/mg/m3/μmol/mol; concentration alarm threshold
responsive gasAlkanes: such as methane, ethane, etc.Aromatic hydrocarbons: such as benzene, toluene, xylene, etc.Olefins: such as ethylene, propylene, etc.Halogenated hydrocarbons: such as chloroform, dichloromethane, etc.Ester compounds: such as ethyl acetate, acetone, etc.Aldehydes: such as formaldehyde, acetaldehyde, etc.Ketones: such as acetone, butanone, etc.Other compounds: such as naphthalene, pyridine, etc.
hydrogen gas source 
Storage methodLow pressure solid state hydrogen storage alloy cylinder
working pressure0.1-1.0MPa
hydrogenation pressure0.7MPa
hydrogen purity99.99% of H2 is used for FID
Hydrogen cylinder capacityUp to 10L per bottle at room temperature
hydrogen working timeContinuous working time ≥10 h/bottle; at-20°C, usage duration ≥4 h/bottle
hydrogenation timeWhen hydrogen is generated by hydrogen generator at room temperature, the hydrogen charging time is 3.5 h.When hydrogen is filled into the high-pressure cylinder, the duration is 0
Temperature detectionTemperature detection mode, low-temperature auxiliary heating at-10°C
storage temperature0℃-40℃
life lengthUnder normal operating conditions, the hydrogen charging and discharging cycles should be ≥2000 times.
safetyair transport safety certification
size85 mm ×φ22 mm
weight≤0.1kg
source 
safetyCE/FCC/IEC62133/UN38.3/REACH/RoHS/(EU) 2023/1542/CCC
charging intervalThe battery charges to 85% in 5 hours, with an LED indicator showing the charge level.
charging temperature0°C to +45°C
charging systemPower adapters support both direct charging and wall charging, with a 12V car charger adapter available as an option.
cell voltage7.4V
battery capacity6600mAh at 20°C to 25°C
Battery runtime25°C ambient temperature and approximately 10 hours for general use-20°C low temperature, usage duration ≥4h
Battery typeLithium-ion battery, replaceable on-site, with integrated LED SOC indicator
mains switchLong press 3 seconds to power on/off
communication and data storage 
communication interfaceUSB 2.0, Bluetooth, Wi-Fi
mediuminternal flash memory card
joggleUpdate from USB device, transfer data from / to PC
SCStandard 32GB; expandable to 64GB or 128GB
file formatStandard Excel (sequence, detection time, maximum value), image (jpg), video (mp4))
Camera 
digital camera5MP with built-in LED flash for photos and videos
Capture ModeSupports single-frame and timed shooting (60 seconds)
Scan Code 32Supports scanning QR codes as labels
NotesSupports voice notes, text notes, and tag notes
Local GalleryView, edit, and delete captured images and videos
image superimposition informationDisplay real-time value, maximum value, average value, time, location, and device model
Start command (trigger key)Regular mode:1. On the detection interface, tap the main trigger once to record and save the current maximum value, then clear it.Single-frame shooting mode:1. Take a photo on the detection interface to access the real-time image screen. Press the main trigger once to freeze the image.2. While the screen is frozen, press the main trigger once to save the real-time detection image to the Micro-SD card. (Press the return key to return to normal mode)In recording (MP4) mode:1. Press the recording shortcut key on the detection interface to enter the real-time image screen. Press the main trigger once to start recording. (Press the return key to return to normal mode)2. During video recording (recording function automatically enabled), press the main trigger once to stop the recording process and save the video to the memory card. (The system defaults to recording for 60 seconds, then stops and saves automatically.)  
set up 
Detector modeUser selection, detection mode automatically matched
Switch unitSupports switching between ppm, mg, m3, and μmol/mol; allows unified unit export
warning thresholdUser-defined input, automatically matched detection mode
data storageManual/Auto
Auto Storage IntervalUser adjustable (auto save mode)
CommunicationSupports on/off selection
camera shootingSupports on/off selection
take a pictureEnable/Disable automatic maximum value photo capture
Display informationOptional (real-time value, maximum value, average value, time, position, background value)
LED headlampSupports on/off selection
shut down purgeSupports on/off selection
automatic calibrationSupports on/off selection
unit of measureSupports ppm/ppb selection
user interface 
display screen3.5-inch 4:3 color LCD touchscreen with 640×480 resolution and backlighting
key▲Up, ▼Down, Enter for confirmation, power on/off, Exit, take photos, record videos, shortcut keys; Trigger key; AI voice commands;
textPredefined list or touchscreen keyboard
languageChinese/English
additional function 
shortcut menuFlash, Volume, Screen Brightness, Photo, Video, Blowout
LED headlampSupports flashlight and flash modes
Beidou positioningSupport (optional)
loudspeakerIt can play audio files or voice annotations, and trigger an alarm sound for over-limit alerts.Voice alert
microphoneAdd a 60-second audio annotation to a still image or video
convention 
detectorFID (Flame Ionization Detector)
Package content1 host unit, 1 battery charger, 1 sampling probe, 2 hydrogen storage alloy cylinders, 2 detachable batteries, 1 pressure relief valve, 3 standard gas bags, 1 sintering filter, 1 wrist strap, 1 disassembly tool (for cleaning the sintering filter), 1 protective case, 1 pressure gauge, 10 filter membranes, 1 data cable, 1 set of printed documents (instruction manual, certificate of conformity, factory inspection report, shipping list)
apolegamy 
Hydrogen toolsElectrolysis water hydrogen generator (hydrogen production and charging require only pure water)
tool adjustmentPortable Calibrator (Simple and Quick One-Click Calibration)
cloud servicesThe VOC Integrated Management Platform enables secure and direct data upload, organization, storage, and management.The infrared thermal imaging leak detector enables direct and secure data transmission via Wi-Fi for uploading, organizing, storing, and sharing (requires the necessary firmware).
RFIDIt can be integrated with the instrument inventory management platform software to achieve intelligent management of instruments.
Environment and Certification 
storage temperature range-30°C to 60°C
levels of protectionIP66 GB/T 4208 Enclosure Protection Rating (IP Code)
meets hazardous location certificationEx db  ia IIC T4 GbGB/T3836-2021 Electrical equipment for explosion-proof environments-Part 1-4
operating temperature range-25°C to 50°C
drop and vibration resistanceDesigned for a drop resistance of 1 m; Vibration: 2 g (IEC 60068-2-6)
attestationSIL functional safety certification
applied code 
HJ 1012-2018Technical Requirements and Detection Methods for Portable Monitoring Instruments of Total Hydrocarbons, Methane and Non-methane Total Hydrocarbons in Ambient Air and Exhaust Gas
HJ 1230-2021Technical Guidelines for Detection and Repair of Volatile Organic Compounds Leaks in Industrial Enterprises
HJ733-2014Technical Guidelines for Detection of Volatile Organic Compounds from Leakage and Open Liquid Surface Discharge
GB 37822-2019Control Standard for Volatile Organic Compounds Unorganized Emissions
Compared with national standards 
essential parameterNational standards require:product standard :Comparison results
range abilitynot have0~50,000 μmol/mol (adjustable range) 
resolution rationot have0.01μmol/mol 
quantitative repeatability≤2.0% (methane)≤1.0% (methane)ample
linear error≤2.0% of the full range (methane)≤1.5% of the full range (methane)ample
parallelism of instruments≤5.0%≤2.0%ample
sampling flowWithin the range of 0.1 to 3.0 liters per minute0.7L/minsatisfied
indicating error<10%<3%ample
response time<10s<3sample
instrument stability<10%<5%4hample
zero point indication<±10μmol/mol<±1μmol/molample

04 application area:

  • Petroleum refining and related industries such as petrochemicals, chemical engineering, pharmaceutical manufacturing, surface coating, printing, and packaging
  • LDAR (Leak Detection and Repair) detection
  • rapid monitoring of stationary pollution sources
  • Effect Evaluation of VOCs Treatment Facilities
  • VOCs traceability investigation
  • VOCs Detection in Factory Workshop Environment
  • Detection of VOCs Emission from Wastewater Tank
  • unorganized on-site emergency testing
  • On-site investigation of oil vapor recovery in gas station and oil depot

Tags: