The M3 is an innovative hydrogen flame ionization detector (FID) analyzer. Smaller, lighter, and with extended battery life, it is specifically designed for LDAR detection. The analyzer is suitable for monitoring hydrocarbon, methane (CH₄), and volatile organic compound (VOC) emissions across multiple stages of the petroleum and natural gas supply chain, as well as other industrial sectors.

Share:

Product Introduction

The M3 is further optimized based on the OM3000, featuring a smaller and lighter design with extended battery life, and is specifically designed for LDAR detection.

01 Product features:

  • Compact and ultra-lightweight:

The world’s smallest and lightest professional-grade VOC detector with FID technology.

Weighing ≤1.25kg, it is at least twice as light as comparable products.         

  • stability :

The micro EPC maintains constant current to regulate hydrogen flow rate, ensuring stable FID combustion with minimal flameout risk.

The revolutionary quantitative analysis function reduces preheating time by several orders of magnitude and improves calibration efficiency.

  • Security and convenience:

The system features both intrinsically safe and explosion-proof designs, with an explosion-proof rating of Ex db ia IIC T4 Gb.

The system features replaceable low-pressure solid-state hydrogen storage tanks, enabling simple and convenient hydrogen charging with hassle-free storage and transportation.

  • Super battery life:

Replaceable batteries and high-capacity gas cylinders with continuous operation>20 hours per cylinder;

  • Feature extension:

Optional sensors for PID, oxygen, carbon monoxide, carbon dioxide, sulfur dioxide, and hydrogen sulfide can be installed.

RFID electronic tags are optional, which can be integrated with the instrument inventory management platform software to enable intelligent instrument management.

Configure inspection assistant

02 after-sale service:

  • Free Quick Backup: Your device is covered for 1 year, with free backup service provided during the warranty period.
  • Enjoy free annual factory maintenance and lifetime repairs, with only spare parts costs charged.

03

essential parameterParameter range
product descriptionM3 Portable Total Hydrocarbon Analyzer/Volatile Organic Compounds Analyzer
Measured componentMost organic and inorganic compounds
Detector typeFID and PID/O2/CO/SO2/H2S (optional)
Precision modeppm/ppb
InteractionBuilt-in color LCD display with backlight; four buttons
Range (ppm)FID: 0~50,000 μmol/mol methane (adjustable range) 
linearity rangeFID: 0~50,000 μmol/mol of methane
Input/OutputBluetooth, Wi-Fi, USB
goingEnvironmental temperature: -25°C to +50°C; Relative humidity (0% to 95% RH)
dynamic pressure compensationAutomatic Dynamic Adaptation of Sampling Pressure
duration of flight+25°C ambient temperature and approximately 15 hours for general use
Total weight (including battery and gas cylinder)1.25±0.05 kg
Machine size200×182×59 mm
detector 
Accuracy (display error)FID: ±2% of the instrument reading, for methane concentrations ranging from 1.0 to 10,000 ppm;The error of the detector reading is ≤±5% at 50℃ and-20℃.
linear errorFID: ±2% ;
resolution ratio0.01μmol/mol
repetitivenessFID: Instrument ± 2% (500 ppm methane)
stabilityThe instrument operated continuously for 8 hours, with a measurement drift of ≤ ±5%.
detection limitThe lower limit of detection was defined as seven times the standard deviation of the interpeak noise.FID instrument-0.5 ppm methane
sampling velocityThe nominal values are displayed at the sample probe inlet, ranging from 0.1 to 1.0 L/min, with a rated flow rate of 0.7 L/min, positive pressure of 50 kPa, and negative pressure of-40 kPa.
preheating time≤5min
FID actual lifeApproximately 6000 hours
Measurement and Analysis 
calibration of measurementSupports multi-point calibration with a minimum of two points
calibration validityApproximately 168 hours for general use (drift ±5%)
Response time (T90)sensitivityFID: Achieves 90% of the final value in less than 3.0 seconds when using 10,000ppm methane 
Reset time (T90)sensitivityFID: Achieves 90% of the final value in less than 3.0 seconds when using 10,000ppm methane 
take notesReal-time values, maximum values (manual clearing, automatic storage), average values, curve trend,
Testing unitLocalized unit adjustment, ppm/mg/m3/μmol/mol; concentration alarm threshold
responsive gasAlkanes: such as methane, ethane, etc.Aromatic hydrocarbons: such as benzene, toluene, xylene, etc.Olefins: such as ethylene, propylene, etc.Halogenated hydrocarbons: such as chloroform, dichloromethane, etc.Ester compounds: such as ethyl acetate, acetone, etc.Aldehydes: such as formaldehyde, acetaldehyde, etc.Ketones: such as acetone, butanone, etc.Other compounds: such as naphthalene, pyridine, etc.
hydrogen gas source 
Storage methodLow pressure solid state hydrogen storage alloy cylinder
working pressure0.1-1.0MPa
hydrogenation pressureRated pressure: 0.7 MPa, adjustable range: 0.6-3MPa
hydrogen purity99.995% of H2 is used for FID
Hydrogen cylinder capacityIt can reach 20L at room temperature.
hydrogen flow rateRated flow rate of 60 mL/min
amount of hydrogen released300 to 500 mL/min (depending on the remaining hydrogen supply)
hydrogen working timeContinuous operation time approximately 20 hours; at-20°C low temperature, usage duration ≥4 hours
hydrogenation timeWhen hydrogen is generated at room temperature, the hydrogen generation time is 5 hours.When hydrogen is charged into the high-pressure cylinder, the duration is 0.5 hours.
Temperature detectionTemperature detection mode, with auxiliary heating for cryogenic cylinders at-10°C
storage temperature0℃-40℃
life lengthUnder normal operating conditions, the hydrogen charging and discharging cycles should be ≥2000 times.
safetyair transport safety certification
source 
charging intervalThe LED indicator shows 85% charge in 5 hours.
charging temperature0°C to +45°C
charging systemThe power adapter supports direct charging, with an optional 12V car charger available.
cell voltage7.4V
battery capacity5000mAh at 20°C to 25°C
Battery runtime25°C ambient temperature and approximately 13 hours for general use-20°C low temperature, usage duration ≥4h
Battery typelithium ion
mains switchShort press to power on, long press 5 seconds to power off
communication and data storage 
communication interfaceUSB 2.0, Bluetooth, Wi-Fi
mediuminternal flash memory card
joggleUpdate from PC device Transfer data from/to PC
SC8GB 1 million data entries
file formatStandard Excel sequence: Detect date and time, real-time value, maximum value, and unit
set up 
Detector modeUser selection, detection mode automatically matched
Switch unitSupports switching between ppm, mg, m3, and μmol/mol; allows unified unit export
warning thresholdUser-defined input, automatically matched detection mode
data storageManual/Auto
Auto Storage IntervalUser-adjustable (Auto mode)
CommunicationSupports on/off selection
shut down purgeSupports on/off selection
automatic calibrationSupports on/off selection
unit of measureSupports ppm/ppb selection
user interface 
display screenColor LCD display with backlight
key▲Up ▼Down Enter to confirm Exit to return Power switch
languageChinese/English
Display interface (APP) 
status barBluetooth/WIFI connection, current location, battery level, time
firingNote: Instrument self-check in progress. Ignition succeeded or failed. Check (pump stopped).
turn off the firePrompt: Prepare to turn off the fire, yes/no (default: yes); turn off the fire prompt
calibrationManual calibration: Current signal value, current concentration value, calibration status: Supports displaying 6 curves, clearing calibration curves, entering calibration (user-defined values), saving calibration (opens the detection interface after saving). Note: If the current concentration value or input value is outside the set range, recalibrate.Auto-calibration: Based on the device’s stable signal value, the built-in calibration curve enables one-click calibration.
checkFID real-time value: Set the threshold in the interface. A red flashing alert appears when the real-time value exceeds the threshold.FID maximum value: 1. Save the real-time value and maximum value within 10 seconds, with the maximum value automatically updated every 5 seconds (automatic save mode). 2. Press Enter to save the current real-time value and maximum value, and clear the current maximum value (manual hold mode). Note: Data saved successfully.FID average: Displays the FID average when no other sensors are present, or real-time values from other sensors (sensor type retrieved from the interface’s sensor settings).Background value: Displays the FID detection environment background value when no other sensors are present (the displayed value is associated with the background value detection). Displays the maximum value when other sensors are present (sensor type is obtained from the sensor settings interface).
background levelNote: Background value detection in progress. Background value detection completed (background value automatically cleared after power on/off).Settings: Detect only/Detect and deduct background values
look overData view: Sequence, Detection time, Date, Real-time value, Maximum value, Unit, Quantity, Storage capacity;Curve trend: FID real-time detection trend;Instrument operating parameters: background value, current signal value, FID flame temperature, host temperature, hydrogen pressure, pump pressure, power consumption, storage capacity;Instrument information: Device name, model, software version, instrument serial number, Bluetooth address, memory, screenService Guide: After-sales, Quick Start Guide; Beginner Mode
set upUnit settings: ppm, mg/m3, μmol/mol. Default: ppmThreshold setting: The keyboard exits automatically after the selection is confirmed. Default setting: 0Data saving: Manual/Auto. Default: ManualAuto-save interval: The keyboard automatically exits after you select and confirm. Default setting: 10 seconds per group. It will close automatically in manual mode.Other detectors: None/PID/Oxygen/Carbon monoxide/Sulfur dioxide/Hydrogen sulfide. Default setting: NoneBackground value settings: Only detect / Detect with deduction. Default settings: Only detect displayCommunication settings: On/Off, Default: OffShut-off purging: On/Off, default setting: OffPump pressure settings: high, medium, lowHydrogen pressure settings: high, medium, lowData management: Auto delete when full capacity On/OffScreen brightness: Increase or decreaseSave settings: Save settings prompt: Settings completedRemote Upgrade: Upgrade software or monitor devices via the APP
convention 
detectorFID (Flame Ionization Detector)
Package content1 host unit, 1 battery charger, 1 sampling probe, 2 hydrogen storage alloy cylinders, 1 cylinder inflation valve, 3 standard gas bags, 1 sintered filter, 1 wrist strap, 1 disassembly tool (for cleaning the sintered filter), 1 protective case, 1 pressure gauge, 10 filter membranes, 1 data cable, 1 set of printed documents (instruction manual, certificate of conformity, factory inspection report, quick start guide, shipping list)
apolegamy 
Hydrogen toolsElectrolysis water hydrogen generator (hydrogen production and charging require only pure water)
tool adjustmentPortable Calibrator (Simple and Quick One-Click Calibration)
Compatible with AOMA softwareLDAR Management App (Explosion-proof Handheld Device)
 VOCs Monitoring App (Explosion-proof Manual Operator)
cloud servicesThe LDAR integrated management platform enables direct and secure data upload, organization, storage, and management.
RFIDIt can be integrated with the instrument inventory management platform software to achieve intelligent management of instruments.
Environment and Certification 
storage temperature range-30°C to 60°C
levels of protectionIP66 GB/T 4208 Enclosure Protection Rating (IP Code)
meets hazardous location certificationEx db ia IIC T4 GbGB/T3836-2021 Electrical equipment for explosion-proof environments-Part 1-4
operating temperature range-25°C to 50°C
drop and vibration resistanceDesigned for a drop resistance of 1 m; Vibration: 2 g (IEC 60068-2-6)
attestationSIL functional safety certification
applied code 
HJ 1012-2018Technical Requirements and Detection Methods for Portable Monitoring Instruments of Total Hydrocarbons, Methane and Non-methane Total Hydrocarbons in Ambient Air and Exhaust Gas
HJ 1230-2021Technical Guidelines for Detection and Repair of Volatile Organic Compounds Leaks in Industrial Enterprises
HJ 733-2014Technical Guidelines for Detection of Volatile Organic Compounds from Leakage and Open Liquid Surface Discharge
GB 37822-2019Control Standard for Volatile Organic Compounds Unorganized Emissions
Compared with national standards 
essential parameterNational standards require:product standard :Comparison results
range abilitynot have0~50,000 μmol/mol (adjustable range) 
resolution rationot have0.01μmol/mol 
quantitative repeatability≤2.0% (methane)≤1.0% (methane)ample
linear error≤2.0% of the full range (methane)≤1.5% of the full range (methane)ample
parallelism of instruments≤5.0%≤2.0%ample
sampling flowWithin the range of 0.1 to 3.0 liters per minute0.7L/minsatisfied
indicating error<10%<3%ample
response time<10s<3sample
instrument stability<10%<5%4hample

04 application area:

  • Petroleum refining and related industries such as petrochemicals, chemical engineering, pharmaceutical manufacturing, surface coating, printing, and packaging
  • LDAR (Leak Detection and Repair) detection
  • rapid monitoring of stationary pollution sources
  • Effect Evaluation of VOCs Treatment Facilities
  • VOCs traceability investigation
  • VOCs Detection in Factory Workshop Environment
  • Detection of VOCs Emission from Wastewater Tank
  • unorganized on-site emergency testing
  • On-site investigation of oil vapor recovery in gas station and oil depot