The M3 is an innovative hydrogen flame ionization detector (FID) analyzer. Smaller, lighter, and with extended battery life, it is specifically designed for LDAR detection. The analyzer is suitable for monitoring hydrocarbon, methane (CH₄), and volatile organic compound (VOC) emissions across multiple stages of the petroleum and natural gas supply chain, as well as other industrial sectors.






Product Introduction
The M3 is further optimized based on the OM3000, featuring a smaller and lighter design with extended battery life, and is specifically designed for LDAR detection.
01 Product features:
- Compact and ultra-lightweight:
The world’s smallest and lightest professional-grade VOC detector with FID technology.
Weighing ≤1.25kg, it is at least twice as light as comparable products.
- stability :
The micro EPC maintains constant current to regulate hydrogen flow rate, ensuring stable FID combustion with minimal flameout risk.
The revolutionary quantitative analysis function reduces preheating time by several orders of magnitude and improves calibration efficiency.
- Security and convenience:
The system features both intrinsically safe and explosion-proof designs, with an explosion-proof rating of Ex db ia IIC T4 Gb.
The system features replaceable low-pressure solid-state hydrogen storage tanks, enabling simple and convenient hydrogen charging with hassle-free storage and transportation.
- Super battery life:
Replaceable batteries and high-capacity gas cylinders with continuous operation>20 hours per cylinder;
- Feature extension:
Optional sensors for PID, oxygen, carbon monoxide, carbon dioxide, sulfur dioxide, and hydrogen sulfide can be installed.
RFID electronic tags are optional, which can be integrated with the instrument inventory management platform software to enable intelligent instrument management.
Configure inspection assistant
02 after-sale service:
- Free Quick Backup: Your device is covered for 1 year, with free backup service provided during the warranty period.
- Enjoy free annual factory maintenance and lifetime repairs, with only spare parts costs charged.
03
| essential parameter | Parameter range | |||
| product description | M3 Portable Total Hydrocarbon Analyzer/Volatile Organic Compounds Analyzer | |||
| Measured component | Most organic and inorganic compounds | |||
| Detector type | FID and PID/O2/CO/SO2/H2S (optional) | |||
| Precision mode | ppm/ppb | |||
| Interaction | Built-in color LCD display with backlight; four buttons | |||
| Range (ppm) | FID: 0~50,000 μmol/mol methane (adjustable range) | |||
| linearity range | FID: 0~50,000 μmol/mol of methane | |||
| Input/Output | Bluetooth, Wi-Fi, USB | |||
| going | Environmental temperature: -25°C to +50°C; Relative humidity (0% to 95% RH) | |||
| dynamic pressure compensation | Automatic Dynamic Adaptation of Sampling Pressure | |||
| duration of flight | +25°C ambient temperature and approximately 15 hours for general use | |||
| Total weight (including battery and gas cylinder) | 1.25±0.05 kg | |||
| Machine size | 200×182×59 mm | |||
| detector | ||||
| Accuracy (display error) | FID: ±2% of the instrument reading, for methane concentrations ranging from 1.0 to 10,000 ppm;The error of the detector reading is ≤±5% at 50℃ and-20℃. | |||
| linear error | FID: ±2% ; | |||
| resolution ratio | 0.01μmol/mol | |||
| repetitiveness | FID: Instrument ± 2% (500 ppm methane) | |||
| stability | The instrument operated continuously for 8 hours, with a measurement drift of ≤ ±5%. | |||
| detection limit | The lower limit of detection was defined as seven times the standard deviation of the interpeak noise.FID instrument-0.5 ppm methane | |||
| sampling velocity | The nominal values are displayed at the sample probe inlet, ranging from 0.1 to 1.0 L/min, with a rated flow rate of 0.7 L/min, positive pressure of 50 kPa, and negative pressure of-40 kPa. | |||
| preheating time | ≤5min | |||
| FID actual life | Approximately 6000 hours | |||
| Measurement and Analysis | ||||
| calibration of measurement | Supports multi-point calibration with a minimum of two points | |||
| calibration validity | Approximately 168 hours for general use (drift ±5%) | |||
| Response time (T90)sensitivity | FID: Achieves 90% of the final value in less than 3.0 seconds when using 10,000ppm methane | |||
| Reset time (T90)sensitivity | FID: Achieves 90% of the final value in less than 3.0 seconds when using 10,000ppm methane | |||
| take notes | Real-time values, maximum values (manual clearing, automatic storage), average values, curve trend, | |||
| Testing unit | Localized unit adjustment, ppm/mg/m3/μmol/mol; concentration alarm threshold | |||
| responsive gas | Alkanes: such as methane, ethane, etc.Aromatic hydrocarbons: such as benzene, toluene, xylene, etc.Olefins: such as ethylene, propylene, etc.Halogenated hydrocarbons: such as chloroform, dichloromethane, etc.Ester compounds: such as ethyl acetate, acetone, etc.Aldehydes: such as formaldehyde, acetaldehyde, etc.Ketones: such as acetone, butanone, etc.Other compounds: such as naphthalene, pyridine, etc. | |||
| hydrogen gas source | ||||
| Storage method | Low pressure solid state hydrogen storage alloy cylinder | |||
| working pressure | 0.1-1.0MPa | |||
| hydrogenation pressure | Rated pressure: 0.7 MPa, adjustable range: 0.6-3MPa | |||
| hydrogen purity | 99.995% of H2 is used for FID | |||
| Hydrogen cylinder capacity | It can reach 20L at room temperature. | |||
| hydrogen flow rate | Rated flow rate of 60 mL/min | |||
| amount of hydrogen released | 300 to 500 mL/min (depending on the remaining hydrogen supply) | |||
| hydrogen working time | Continuous operation time approximately 20 hours; at-20°C low temperature, usage duration ≥4 hours | |||
| hydrogenation time | When hydrogen is generated at room temperature, the hydrogen generation time is 5 hours.When hydrogen is charged into the high-pressure cylinder, the duration is 0.5 hours. | |||
| Temperature detection | Temperature detection mode, with auxiliary heating for cryogenic cylinders at-10°C | |||
| storage temperature | 0℃-40℃ | |||
| life length | Under normal operating conditions, the hydrogen charging and discharging cycles should be ≥2000 times. | |||
| safety | air transport safety certification | |||
| source | ||||
| charging interval | The LED indicator shows 85% charge in 5 hours. | |||
| charging temperature | 0°C to +45°C | |||
| charging system | The power adapter supports direct charging, with an optional 12V car charger available. | |||
| cell voltage | 7.4V | |||
| battery capacity | 5000mAh at 20°C to 25°C | |||
| Battery runtime | 25°C ambient temperature and approximately 13 hours for general use-20°C low temperature, usage duration ≥4h | |||
| Battery type | lithium ion | |||
| mains switch | Short press to power on, long press 5 seconds to power off | |||
| communication and data storage | ||||
| communication interface | USB 2.0, Bluetooth, Wi-Fi | |||
| medium | internal flash memory card | |||
| joggle | Update from PC device Transfer data from/to PC | |||
| SC | 8GB 1 million data entries | |||
| file format | Standard Excel sequence: Detect date and time, real-time value, maximum value, and unit | |||
| set up | ||||
| Detector mode | User selection, detection mode automatically matched | |||
| Switch unit | Supports switching between ppm, mg, m3, and μmol/mol; allows unified unit export | |||
| warning threshold | User-defined input, automatically matched detection mode | |||
| data storage | Manual/Auto | |||
| Auto Storage Interval | User-adjustable (Auto mode) | |||
| Communication | Supports on/off selection | |||
| shut down purge | Supports on/off selection | |||
| automatic calibration | Supports on/off selection | |||
| unit of measure | Supports ppm/ppb selection | |||
| user interface | ||||
| display screen | Color LCD display with backlight | |||
| key | ▲Up ▼Down Enter to confirm Exit to return Power switch | |||
| language | Chinese/English | |||
| Display interface (APP) | ||||
| status bar | Bluetooth/WIFI connection, current location, battery level, time | |||
| firing | Note: Instrument self-check in progress. Ignition succeeded or failed. Check (pump stopped). | |||
| turn off the fire | Prompt: Prepare to turn off the fire, yes/no (default: yes); turn off the fire prompt | |||
| calibration | Manual calibration: Current signal value, current concentration value, calibration status: Supports displaying 6 curves, clearing calibration curves, entering calibration (user-defined values), saving calibration (opens the detection interface after saving). Note: If the current concentration value or input value is outside the set range, recalibrate.Auto-calibration: Based on the device’s stable signal value, the built-in calibration curve enables one-click calibration. | |||
| check | FID real-time value: Set the threshold in the interface. A red flashing alert appears when the real-time value exceeds the threshold.FID maximum value: 1. Save the real-time value and maximum value within 10 seconds, with the maximum value automatically updated every 5 seconds (automatic save mode). 2. Press Enter to save the current real-time value and maximum value, and clear the current maximum value (manual hold mode). Note: Data saved successfully.FID average: Displays the FID average when no other sensors are present, or real-time values from other sensors (sensor type retrieved from the interface’s sensor settings).Background value: Displays the FID detection environment background value when no other sensors are present (the displayed value is associated with the background value detection). Displays the maximum value when other sensors are present (sensor type is obtained from the sensor settings interface). | |||
| background level | Note: Background value detection in progress. Background value detection completed (background value automatically cleared after power on/off).Settings: Detect only/Detect and deduct background values | |||
| look over | Data view: Sequence, Detection time, Date, Real-time value, Maximum value, Unit, Quantity, Storage capacity;Curve trend: FID real-time detection trend;Instrument operating parameters: background value, current signal value, FID flame temperature, host temperature, hydrogen pressure, pump pressure, power consumption, storage capacity;Instrument information: Device name, model, software version, instrument serial number, Bluetooth address, memory, screenService Guide: After-sales, Quick Start Guide; Beginner Mode | |||
| set up | Unit settings: ppm, mg/m3, μmol/mol. Default: ppmThreshold setting: The keyboard exits automatically after the selection is confirmed. Default setting: 0Data saving: Manual/Auto. Default: ManualAuto-save interval: The keyboard automatically exits after you select and confirm. Default setting: 10 seconds per group. It will close automatically in manual mode.Other detectors: None/PID/Oxygen/Carbon monoxide/Sulfur dioxide/Hydrogen sulfide. Default setting: NoneBackground value settings: Only detect / Detect with deduction. Default settings: Only detect displayCommunication settings: On/Off, Default: OffShut-off purging: On/Off, default setting: OffPump pressure settings: high, medium, lowHydrogen pressure settings: high, medium, lowData management: Auto delete when full capacity On/OffScreen brightness: Increase or decreaseSave settings: Save settings prompt: Settings completedRemote Upgrade: Upgrade software or monitor devices via the APP | |||
| convention | ||||
| detector | FID (Flame Ionization Detector) | |||
| Package content | 1 host unit, 1 battery charger, 1 sampling probe, 2 hydrogen storage alloy cylinders, 1 cylinder inflation valve, 3 standard gas bags, 1 sintered filter, 1 wrist strap, 1 disassembly tool (for cleaning the sintered filter), 1 protective case, 1 pressure gauge, 10 filter membranes, 1 data cable, 1 set of printed documents (instruction manual, certificate of conformity, factory inspection report, quick start guide, shipping list) | |||
| apolegamy | ||||
| Hydrogen tools | Electrolysis water hydrogen generator (hydrogen production and charging require only pure water) | |||
| tool adjustment | Portable Calibrator (Simple and Quick One-Click Calibration) | |||
| Compatible with AOMA software | LDAR Management App (Explosion-proof Handheld Device) | |||
| VOCs Monitoring App (Explosion-proof Manual Operator) | ||||
| cloud services | The LDAR integrated management platform enables direct and secure data upload, organization, storage, and management. | |||
| RFID | It can be integrated with the instrument inventory management platform software to achieve intelligent management of instruments. | |||
| Environment and Certification | ||||
| storage temperature range | -30°C to 60°C | |||
| levels of protection | IP66 GB/T 4208 Enclosure Protection Rating (IP Code) | |||
| meets hazardous location certification | Ex db ia IIC T4 GbGB/T3836-2021 Electrical equipment for explosion-proof environments-Part 1-4 | |||
| operating temperature range | -25°C to 50°C | |||
| drop and vibration resistance | Designed for a drop resistance of 1 m; Vibration: 2 g (IEC 60068-2-6) | |||
| attestation | SIL functional safety certification | |||
| applied code | ||||
| HJ 1012-2018 | Technical Requirements and Detection Methods for Portable Monitoring Instruments of Total Hydrocarbons, Methane and Non-methane Total Hydrocarbons in Ambient Air and Exhaust Gas | |||
| HJ 1230-2021 | Technical Guidelines for Detection and Repair of Volatile Organic Compounds Leaks in Industrial Enterprises | |||
| HJ 733-2014 | Technical Guidelines for Detection of Volatile Organic Compounds from Leakage and Open Liquid Surface Discharge | |||
| GB 37822-2019 | Control Standard for Volatile Organic Compounds Unorganized Emissions | |||
| Compared with national standards | ||||
| essential parameter | National standards require: | product standard : | Comparison results | |
| range ability | not have | 0~50,000 μmol/mol (adjustable range) | ||
| resolution ratio | not have | 0.01μmol/mol | ||
| quantitative repeatability | ≤2.0% (methane) | ≤1.0% (methane) | ample | |
| linear error | ≤2.0% of the full range (methane) | ≤1.5% of the full range (methane) | ample | |
| parallelism of instruments | ≤5.0% | ≤2.0% | ample | |
| sampling flow | Within the range of 0.1 to 3.0 liters per minute | 0.7L/min | satisfied | |
| indicating error | <10% | <3% | ample | |
| response time | <10s | <3s | ample | |
| instrument stability | <10% | <5%4h | ample | |
04 application area:
- Petroleum refining and related industries such as petrochemicals, chemical engineering, pharmaceutical manufacturing, surface coating, printing, and packaging
- LDAR (Leak Detection and Repair) detection
- rapid monitoring of stationary pollution sources
- Effect Evaluation of VOCs Treatment Facilities
- VOCs traceability investigation
- VOCs Detection in Factory Workshop Environment
- Detection of VOCs Emission from Wastewater Tank
- unorganized on-site emergency testing
- On-site investigation of oil vapor recovery in gas station and oil depot



Tags:
Related Products
-
OM3500 Handheld Total Hydrocarbon Analyzer for VOCs Leak Detection
Read More
-
Aoma M2 Handheld FID Total Hydrocarbon Analyzer
Read More
-
OM3000 Pro Portable VOC Analyzer for LDAR & Leak Detection
Read More
-
OM3000 Portable VOC Analyzer for LDAR & Leak Detection
Read More
-
M2 Portable Total Hydrocarbon Analyzer
Read More
-
Aoma X5 Portable Total Hydrocarbon Analyzer/Volatile Organic Compounds Analyzer
Read More